DNC three-phase energy meter field calibrator
GY481 Three-phase precision programmable power supp
GY-HG Intelligent Transformer Calibrator
GY9201 AC and DC indicator verification device
GY4501 single-phase energy meter field calibrator
Transformer load box
GYCT standard current transformer
GY series current riser
GYPT standard voltage transformer
GY4500 Secondary Voltage Drop Tester
Technical Specifications |
|||
Input characteristics |
Voltage measurement range |
0 ~ 260V, there are two internal ranges, and the conversion limit is automatically judged by the internal circuit. |
|
Current measuring range |
0 ~ 20A (optional for 200A) |
||
Accuracy |
Voltage |
± 0.2% |
|
Current, power, electric energy |
± 0.5% |
||
Operating temperature |
-10℃~+40℃ |
||
Operating power |
AC, DC90V~260V |
||
insulation |
The insulation resistance of the voltage and current input terminals to the chassis is ≥100MΩ |
Between the input end of the working power supply and the housing, the voltage is 2kV (rms), which lasts for 1 minute. |
|
volume |
25cm×20cm×12cm |
||
weight |
0.6kg |
||
Standard low frequency energy pulse constant |
FL=1250r/kW·h |
Product Features
1. No power off, no change to the measurement circuit, and no opening of the measurement equipment, the comprehensive error
of the online real-load detection measurement equipment (including energy meter, CT, wiring error).
2. It can detect the comprehensive error of the measuring device (including the basic error of the electricity meter, the error of the
transformer and the wiring error), the basic error of the electricity meter, the CT transformation ratio and various electrical parameters.
3. Measure voltage, CT primary and secondary current, power, power factor and other electrical parameters, so as to accurately
analyze and judge the fault of the measuring equipment loop
4. Measure the current of CT primary and secondary side, so that the transformation ratio and error of current transformer can be measured.
5. The current loop is measured with a clamp transformer, and the operator can measure conveniently and safely without disconnecting
the current loop. The limit of the clamp transformer is 15A.
6. Voltage circuit automatic switching limit: the voltage circuit is automatically judged by the internal circuit to the range of the input voltage
and switched to a suitable gear at any time. There will be no damage to the instrument itself due to the test voltage exceeding the limit.
7. When one phase of voltage or current clamp is reversed (that is, the power is negative), the analyzer automatically alarms (loudspeaker sounds).
8. The calibration data is stored for a long time, and the calibration data of 200 tables can be stored at a time. The user can view and delete it
by pressing the button at any time; also can communicate with the computer through the 232 serial port, upload the data, and use the
special background software The form is saved for easy unified management.
9. True clock function, you can check the current date (including week) and time (accurate to seconds) at any time.
10. Large-screen, high-brightness LCD display, equipped with Chinese menu prompts to achieve friendly man-machine dialogue, LCD brightness
can be adjusted by buttons, can adapt to the impact of different seasons on the LCD.