WhatsApp:

87197008

Email Address:

contact@guoyi.com.sg

Tel:+65-93262640

HP:+65-87197008

Home > PRODUCTS > Grounding & Insulation INSTR. > Calibration INSTR >

GY4501 single-phase energy meter field calibrator

Recommended Products
Product Details
 

Technical Specifications

   
 

Input characteristics

Voltage measurement range

0 ~ 260V, there are two internal ranges, and the conversion limit is automatically judged by the internal circuit.

 

Current measuring range

0 20A (optional for 200A)

 

Accuracy

Voltage

± 0.2%

 

Current, power, electric energy

± 0.5%

 

Operating temperature

-10+40

 

Operating power

AC, DC90V260V

 

insulation

The insulation resistance of the voltage and current input terminals to the chassis is ≥100MΩ

Between the input end of the working power supply and the housing, the voltage is 2kV (rms), which lasts for 1 minute.

 

volume

25cm×20cm×12cm

 

weight

0.6kg

 

Standard low frequency energy pulse constant

FL=1250r/kW·h

Product Features

1. No power off, no change to the measurement circuit, and no opening of the measurement equipment, the comprehensive error
   of the online real-load detection measurement equipment (including energy meter, CT, wiring error).

2. It can detect the comprehensive error of the measuring device (including the basic error of the electricity meter, the error of the
    transformer and the wiring error), the basic error of the electricity meter, the CT transformation ratio and various electrical parameters.

3. Measure voltage, CT primary and secondary current, power, power factor and other electrical parameters, so as to accurately
   analyze and judge the fault of the measuring equipment loop

4. Measure the current of CT primary and secondary side, so that the transformation ratio and error of current transformer can be measured.

5. The current loop is measured with a clamp transformer, and the operator can measure conveniently and safely without disconnecting
   the current loop. The limit of the clamp transformer is 15A.

6. Voltage circuit automatic switching limit: the voltage circuit is automatically judged by the internal circuit to the range of the input voltage
   and switched to a suitable gear at any time. There will be no damage to the instrument itself due to the test voltage exceeding the limit.

7. When one phase of voltage or current clamp is reversed (that is, the power is negative), the analyzer automatically alarms (loudspeaker sounds).

8. The calibration data is stored for a long time, and the calibration data of 200 tables can be stored at a time. The user can view and delete it
    by pressing the button at any time; also can communicate with the computer through the 232 serial port, upload the data, and use the
    special background software The form is saved for easy unified management.

9. True clock function, you can check the current date (including week) and time (accurate to seconds) at any time.

10. Large-screen, high-brightness LCD display, equipped with Chinese menu prompts to achieve friendly man-machine dialogue, LCD brightness
     can be adjusted by buttons, can adapt to the impact of different seasons on the LCD.

 

  • Email:contact@guoyi.com.sg
  • Address:2 KALLANG AVENUE 08-30 CT HUB SINGAPORE 339407
  • Hotline:0065-93262640

Copyright © 2002-2020 Guoyi Ebuy Pte.Ltd